The type and routine test are very important for transformer. Open and short circuit test of transformer electrical4u. Commissioning a test for a differential protection scheme. Instrument transformers as a standalone test object, and instrument transformers enclosed in a gis. The vector group test vg is performed in a very similar fashion as the ttr test just that it has to be performed by injecting a balanced three phase voltage, i. After the stability test it is advised not to touch or disturb the ct circuits of both the sides to ensure proper operation of the differential scheme. Stability tests of ref schemes are don e to ensure that all wirings and ct polarities are connected correctly. Transformer stability test, ct in neutral electric power.
Figure 5 shows the result of the curve fitting for core 1, considering the y axis to be the current and x axis to be the. The purchase, preparation, assembly, operation and maintenance of transformers represent a large expense to the power system. Current transformer testing swp check this is the latest process zone version before use. The stability for external faults and operation for internal faults can be. If the measured differential current is high then reserve the polarity of one ct preferably nct. Stability testing of tansformer ref protection scheme. Transformer pd and induced voltage withstand test system. After completing the sensitivity test by reversing the cts, all 3 phase ct connections to be normalized and again ref stability of the ct circuits to be confirmed before concluding the test. Transformer above 2 mva are normally provided with differential protection scheme. The purpose of this article is to help a test set operator understand the tests they perform, and hopefully add or reenforce a test technique to the test technicians repertoire. In order to inject appropriate currents, care must be taken regarding protected power transformer rating data and main ct connections which are used for this particular installation.
Trafostar rated 25 mva or higher, short circuit tested 19962011 31 out of 35 tested units. The relay can be of static typedth31 alsthom or numerical type 7 ut sag the relays have to be tested as per the procedure mentioned in manuals. If we would like to do transformer stability test on ynd11 transformer with one ct conected in neutral of the transformer wye hv side, and inject 400v on lv side of transformer and make 3ph short circuit to ground on hv side, is it neccesary to disconect neutral of. Hi all, we have been doing transformer stability tests at our project. The voltage at rated frequency is applied to that lv side with the help of a variac of variable ratio auto transformer the hv side of the transformer is kept open. Methods for testing transformer differential relays applied to delta. For testing the diffrential schemewe apply a reduced voltage of. Connection on cpc100 will be same as the shown figure. Paul, mn, usa november 11, 2015 tom ernst ge digital energy 4523 jeremiah rd. Namely, if testing is based on injecting only one sequence current component at the time on both ct inputs of the.
It has been developed with the assistance of bureau of reclamation engineers responsible for operating and maintaining transformers at important. These properties can be used to test the numerical differential protection of any manufacturer as described further in this document. In protection engineering testing plays an important role in many aspects. Cts are instrument transformers used for converting primary current into a reduced secondary current for use with meters, relays, control equipment and other instruments the importance of instrument transformer tests is often underestimated. Page 4 of 15 standard work practice sp0518 ver 2 ergon energy corporation limited abn 50 087 646 062 ergon energy queensland pty ltd abn 11 121 177 802 6. The power loss is also a very convenient number when checking the accuracy of measurements. The procedure mention below enables the testing engineer to confirm the correctness wiring. However, to get an insight of this field test on faulty distribution transformers especially in the developing countries a singlephase voltage transformation ratio test, stepup voltage ratio test, insulation resistance test, earthing ground resistance test, dielectric oil test, load test, etc. For testing the diffrential schemewe apply a reduced voltage of 480v on the transformer primary. The connection diagram for open circuit test on transformer is shown in the figure.
Before test we have to extract the dissolved acid in the oil. Series resonances are occurring between leakage reactance of transformer and capacitance to ground. Some standards have temperature limits on the transformer insulation during the test. A typical transformer differential protection scheme is applied. Factory tests not achieving as much winding stress as field conditions 2. Pdf test systems for voltage stability analysis and. The purpose of the switching impulse test as special test is to secure that the insulations between windings, between windings and earth, between line terminals and earth and between different terminals withstand the switching overvoltages, which may occur in service. Additionally covers the proper methods for drawing transformer fluid samples. Testing of transformer differential protection systems.
Testing of transformer differential protection systems world. Magnetization and primary injection test of current transformer for protective relaying jacob tsado 8 current transformers. A read is counted each time someone views a publication summary such as the title, abstract, and list of authors, clicks on a figure, or views or downloads the fulltext. As it checks the quality of material used and the procedure of transformer manufacturing hence provide us details of life of transformer, the transformer behaviour on different faults. Pdf easy method for testing transformer differential relays. Magnetization and primary injection test of current. Table 2 is the summary of the measured values for figure 3, figure 4, and figure 5, under external fault conditions. Consisting of a variable power supply, stepup transformer, and high accuracy metering package controlled by an industrial microprocessor, the tts series is a. This is an unbiased, instantaneous element in the differential circuit with a range of settings expressed as percentages of the nominal current rating. To test the insulation integrity you will need a megohmmeter or hipot rated to produce the specified maximum test voltage. This setting gives more stability during ct saturation for heavy through fault. Primary injection sensitivity tests only minimum of time consumed if results incorrect, secondary injection and ct tests required unable to check. Background temperature rise testing techniques on current transformers can be divided in two major groups, according to their technology.
Understanding transformer abnormal testing certifigroup. Testing of stability of transformer differential scheme. For that we have first to take exactly 1 gram of insulating oil. Recent developments allow the application of transient simulation tools in the substation and with state of the art test equipment. If you are working with a pdf that has been downloaded from the web or generated from a word processing program, you can edit the text in the document on a linebyline basis. Performance test of faulty distribution transformers along. Potential transformers pts are necessary to a power system for metering and protective relaying to convert higher system voltages to lower control voltages that. Phase a is the most remote phase from the oil inlet pipe. Measure and record also the differential or spill current, idiff from the differential relay.
We have been doing transformer stability tests at our project. Some standards permit a winding to open as long as the transformer passes the hipot test. Current transformers play an important role in the monitoring and protection of electrical power systems. Power transformers built for reliability and efficiency. Factory tests are on transformer without load and without cables 3. Transformer stability test procedure a media to get. For the ref protection of a winding, 4 cts are involved, three phase and one neutral e xcept for auto transformers where sometimes 6 cts, 3 phase and 3 neutral may be present. For example, in order to test differential relay stability the injected current must correspond to the ct secondary currents as seen by the differential relay during external disturbances e. Use the following test procedure for pt insulation tests. Testing power transformers highvoltage transformers are some of the most important and expensive pieces of equipment required for operating a power system. This report documents the work of the ieee pes task force on test systems for voltage stability analysis and security assessment. Protection relay testing for commissioning swp check this is the latest process zone version before use. Potential transformer testing ptvt valence electrical.
The switching impulse voltage is generated in conventional impulse voltage generators at. It is typically used for test specimen that have small capacitance and as a result the power factor tan delta of the test circuit is rather high. Repeat the test for the other phases and the other secondary cores. Page 3 of 9 standard work practice sp0507 ver 5 ergon energy corporation limited abn 50 087 646 062 ergon energy queensland pty ltd abn 11 121 177 802 rated knee point voltage 950 volts, maximum secondary winding resistance 3 ohms. As power transformer is highly expensive as well as important part of distribution system. Incorrect ct polarity at the 22 kv ct was suspected because of the following reasons.
The story of transformer stability the transformer stability test used to conform the ct connections for differential and ref protection. Introduces the new technician to and provides critical information for the experienced technician on the basic theory associated with transformers. Silsbee contents t page introduction 317 generalprinciples 318 nullmethod 321 deflectionmethod 325 experimentalresults. In our plant we have installed new mcc with elr and cbct which is detecting some leakage current in the system but it leading to some confusion when to check that in which feeder which is drawing current we put off the whole panel itself but still cbct detecting some leakage current so can anybody ans me, where i am going wrong or how to detect whether its actual leakage or. How to do the ref stability test for power transformers in. A voltmeter, wattmeter, and an ammeter are connected in lv side of the transformer as shown. Effective maintenance test techniques and diagnostic. Acidity test of transformer insulating oil electrical4u. Switch on the supply and measure the currents at the relay terminals.